Features:
- High-Performance Liquid Pipework and Bore Cleaner
- Safely Removes Iron Bacteria, Slime and Odours
- Does not Harm Crops or Plant Life
- Improves Water Supply
- Derived from Renewable Resources
- No Toxic or Hazardous Ingredients
- Safe to Use, Store and Dispose of
- Readily Biodegradable
Not Recommended on Flexibore Systems
Applications:
Triple7 Envirobore can be used to eliminate a variety of different issues including:
- Remove and prevent iron bacteria in water bores, pipes, pumps & filters
- Controls scum, slime and algae growth
- Remove and prevent calcification
- Remove odours from within the water supply
- Improve Water Quality and System Function
Standard Dilution Rates:
METHOD OF APPLICATION
Bores: For an initial flush, pour product directly down bore. Circulate for 4 to 6 hours and leave overnight. Turn on bore and discard first flush (see table below).
ADDITION RATES
BORE SIZE MM | QUANTITY OF triple7 ENVIROBORE PER METRE OF WATER IN THE BORE |
25 | 20 mL |
50 | 80 mL |
80 | 200 mL |
100 | 300 mL |
125 | 480 mL |
150 | 700 mL |
200 | 1.2 Litres |
250 | 2 Litres |
300 | 2.8 Litres |
400 | 5 Litres |
500 | 7.5 Litres |
Repeat as needed. Recommended guidelines only.
For maintenance dose:
Add product at a rate of 1:100,000 parts water (10ml per 1000 litres) to system via EnviroPulse metering pump.
Tanks & Troughs:
Empty most of the water and sludge. Dilute Triple7 Envirobore 1:10 to 1:30 with water and apply to the sides with a broom/brush. Let stand for 30 minutes than scrub the tank base, rinse away all contaminants and refill with clean water.
Unblocking of pipes, drippers and sprays:
Dosing the water will be necessary in these situations. Once-off treatments will help to clear any slime build-up to some degree but thorough cleaning will need the constant addition of product. For first-off restoring of flow, dosing can be set as high as 50 parts per million, then reduced to 10ppm or less.
Removal of Iron Bacteria from Bores and Pumps:
Pour down the amount recommended on the Envirobore label. Dose amount will depend on the bore size and extent of bacterial
growth. Circulate the water by running the pump for 4 – 6 hours, with the outlet pipe redirected back down the bore. Leave the
bore idle for a minimum of 4 hours, preferably overnight. After treatment, the discharge from the bore may be frothy or discoloured, depending on water constituents and bore condition. Dispose of the contaminated water. The water will soon run clear and be usable. Redirect to normal use.
Continual Maintenance:
For continual dosing you will use between 15 – 20 ml of product per 1000 litres of bore water pumped. Place dismantled parts in Triple7 Envirobore (diluted at 1:10 with water) and circulate or agitate until clean. Leave in solution for a minimum of 6 hours, then rinse and reassemble.