Go to cart
Call our Experts - 0800 130 905

Hansen Fast Flo Trough / Tank Valve Long Arm Pack

$27.15

The Hansen Fast Flo Valve is ideally suited to tight fitting environments that demand a more compact sized valve with responsive on / off capabilities, exceptional flow rates and adaptability. The Fast Flo allows a hose attachment to both diffuse and help eliminate noise from the outlet flow and has a tough, reversible, urethane seat which effectively doubles the life of the valve providing a ‘best of class’ valve that’s reliable for the long term.

Details Code Price Quantity  
20mm & 25mm Long Arm Adaptor HFFSV2520S $27.15
 incl GST
15mm Long Arm Adaptor HFFSV15L $27.15
 incl GST
20mm Long Arm Adaptor HFFSV20L $27.15
 incl GST
25mm Long Arm Adaptor HFFSV25L $27.15
 incl GST
View Full Product Page

Features

  • High performance, cost-effective trough/tank valve - 29 psi, 34 l/min
  • The Fast~Flo Short Arm Valve has the highest flow of any valve of its size at 500 kPa (73 psi); it will deliver 56 l/min
  • Ability to attach a diffuser hose to reduce water turbulence & noise in top entry installations & Anti-Syphon Holes to prevent backflow.
  • Designed with an Ezi Bend brass arm to make water level adjustment a breeze
  • Will fit multiple thread & connection combinations 15 - 50mm
  • Reliable with high and low-pressure applications from 0 - 12 bar
  • Durable urethane seat, which is reversible
  • Suitable for top or side entry
  • Manufactured from strong non-corrosive UV stabilised materials

Overview

The Hansen Fast Flo Valve is ideally suited to tight-fitting environments that demand a more compact sized valve with responsive on/off capabilities, exceptional flow rates and adaptability. The Fast Flo allows a hose attachment to both diffuse and helps eliminate noise from the outlet flow and has a tough, reversible, urethane seat that effectively doubles the valve's life, providing a 'best of class' valve that's reliable for the long term.

Hansen Fast Flo Valve Flow Chart
hands_assembling

Trough / Tank Installation:

  • Flush pipelines into a water tank or troughs before installing Fast~Flo Valve into
    new system
  • Isolate the water going to the trough or tank to replace a valve in an existing system.
  • Thread O-Ring end of correct size Long Tail Adaptor into Fast~Flo Valve Body and tighten firmly enough that the O-Ring creates a seal against the Fast~Flo Valve Body face. Do not overtighten.
ff_side_entry

TO CHANGE WATER LEVEL

Adjust the length of the cord at the top of the float. Use the nut & cord on the long arm valve only.

Side Entry Trough/Tank:

  • Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.
  • On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not overtighten.
  • Screw the Cord Nut* onto the Fast~Flo Brass arm.
  • Thread the Cord* through the Fast~Flo Float. Tie the Cord off to achieve the correct water level.

*Cord and Nuts only supplied with long arm version.

ff_top_entry

NOTE: If an existing or moulded threaded inlet in the trough or tank uses a Hansen Standard Adaptor.

Top Entry Trough/Tank

  • Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.
  • On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not overtighten.
  • Screw the Fast~Flo Float onto the Brass Arm, do not bend Brass Arm.
  • hansen floats blue

    Hansen Floats – Blue

    $6.06$10.11
    Select options This product has multiple variants. The options may be chosen on the product page
  • hansen male straight coupling

    Hansen Male Straight Coupling

    $4.67$21.91
    Select options This product has multiple variants. The options may be chosen on the product page
  • Medium Density Male Threaded Coupling

    Hansen Medium Density Male Threaded Coupling

    $4.82$136.24
    Select options This product has multiple variants. The options may be chosen on the product page

How to:

Trough / Tank Installation:

  1. Flush pipe lines into water tank or troughs before installing Fast~Flo Valve into new system
  2. Isolate the water going to the trough or tank to replace valve in an existing system.
  3. Thread O-Ring end of correct size Long Tail Adaptor into Fast~Flo Valve Body and tighten firmly enough that the O-Ring creates a seal against the Fast~Flo Valve Body face. Do not over tighten.

Side Entry Trough/Tank:img

To Change Water Level Adjust length of cord at top of float. Use the nut & cord on the long arm valve only.

  1. Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.
  2. On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not over tighten.
  3. Screw the Cord Nut* onto the Fast~Flo Brass arm.
  4. Thread the Cord* through the Fast~Flo Float. Tie the Cord off to achieve the correct water level.

Top Entry Trough/Tank:img

Note: If there is an existing or moulded threaded inlet in the trough or tank use a Hansen Standard Adaptor.

  1. Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.
  2. On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not over tighten.
  3. Screw the Fast~Flo Float on to the Brass Arm, do not bend Brass Arm